Separate names with a comma.
Only if you have too much timing and have detonation
Could be referring to the length of the case. If you lengthen the case and put in a thicker bearing plate in the front you are actually making a...
I use duct tape in half strips on Adams. Never make a run with it taped.
If you watch the video below of Adam Flamholc's crash into the wall at Route 66 it would make you a believer of the Simpson Hybrid Pro neck...
The Grid don't care as long as no ICT
If I may ask. What is wrong with the old pump? 90% of the problems with them can be fixed by squirting WD-40 into the air inlet. That comes right...
Go up here. You should use these McAmis valve stems also scroll down and watch the video. Billy at McAmis will also tell you what size hole and...
Use a larger gauge wire if the voltage drops too much. Stay away from a relay unless you love inconsistent reaction times
If you can get away without one then do it. Regular relays will slow down your reaction time and are not consistent. If you have to have one then...
Gasoline is very different because of additives added. Methanol is meant to be 100% pure with no additives so should not be any difference from...
Dale, as Daryl as I know they should still require the same jetting if pure alcohol. If they didn't then then wouldn't pass a NHRA fuel test....
I do. You can try starting with a 80 and work down by 10 at a time. Would not go below 50 because you might burn out the clutches in the tranny. A...
Nope, sorry I don't. Call PSI and talk to Norm Drazy or Andy. Norm built it. 480.820.6511
See if this helps. I found this in my old notes. it also compares the Whipple to a PSI C and D PSI "D" is 422 cu.in.per/rev or 6.752 liters...
Let's just check some things. First the Grid should only change the timing 3-4 degrees from a MSD 8. They insert that delay to allow processing...
Jet flow for main jet and nozzles are normally computed at 150 psi so yes you are correct in that your pressure is so low you don't have much flow
Didn't hear back from you. Did I answer all your questions ok?
You need to make sure your bell housing complies with SFI 6.3. Also if you use a spacer that moves it back you need to make sure it still complies...
If you have less than 30 psi then you are probably not atomizing the fuel very well and it is probably dribbling liquid down the sides of the...
A pump loop is also called a pump sizer and is used to get rid of excess fuel and get the main jet down into a good range like .075 to .105 size...